T50 Gas Tanks

Designed for the transportation of non-refrigerated liquefied gases

SAFE TRANSPORT OF HAZARDOUS GASES

Our fleet of ISO T50 Gas Tanks are suitable for the intermodal and safe transportation of liquefied gases and chemicals under pressure, such as LPG, Propane, Butane, Anhydrous Ammonia, Propylene, Butadiene and Sulphur Dioxide.

Our T50s are available in 24,600 litre (22 Bar & 27.5 bar) and 24,300 litre (34.4 bar). Tanks can be used for domestic and international transport and for filling, draining, and temporary or back-up storage of liquefied gases.

Tanks in accordance with: T50 UN PORTABLE TANK (per special permit), TC IMPACT APPROVED, UIC, IMDG, RID/ADR, CSC, US-DOT, TIR, AAR 600, ISO, CFR49 with DOT SP14578, ISO1496/3

The authorised Dangerous Goods Advisor should confirm fitness for purpose of any tank and that the cargo is compatible and will not attack the tank vessel. Tank containers are supplied in accordance with a signed lease and Seaco General Trading Terms.

Overview

  • Design Code: AMSE VIII Division 2 – Stamp U2, with dual pressure calculation. The ASME U2 stamp is for unfired pressure vessels and compliant to ASME’s guidelines including design, fabrication, inspection, and testing, to meet U.S. regulations.
  • Safety Relief Valve: 80mm / 3 inch diameter device set at working pressure. Rupture disc and pressure gauge fitted. To help protect the tank from accidental over-pressure and implosion from unwanted vacuum conditions.
  • Sunshield: Marine Grade Aluminium Sunshield is fitted at the top of the tank shell fastened with strips, to help protect the cargo from UV light penetration from the sun.
  • Baffle Options: Vertical or Horizontal baffle configurations available to help improve safety in the anti-slosh performance in tank containers that can be caused by sudden driving conditions such as braking and cornering.
  • Bottom Discharge Assembly: With 3 Closures and standard couplings (Liquid and Gas Lines).  All valves are fitted below the liquid level and grouped together.
  • Locking Valve Protection Cabinet: Stainless steel bottom cabinet with aluminium door.
  • Liquid Phase Valve: Stainless steel, 50mm / 2 inch diameter, ball valve with ACME coupling 3 ¼ inch and cap closure.
  • Gas Phase Valve: Stainless steel, 50mm / 2 inch diameter, ball valve with ACME coupling 1 ¾ inch and cap closure.
  • Internal Zinc Coating (optional): Zinc coating provides a barrier and stops moisture from penetrating the base metal, preventing rust and helping to preserve the tanks structural integrity.
  • Level Gauge (optional): Level gauges measure the fluid or gas levels in the tank and monitor if there is any leakages or release of hazardous gas.
SELECT A MEASUREMENT
FRAME DIMENSIONS
External Length6,058 mm
External Width2,438 mm
External Height2,591 mm
External Length20 ft
External Width8 ft
External Height8 ft 6 ins
CAPACITIES
22.0 bar24,600 ltr
27.5 bar24,600 ltr
34.4 bar21,000 ltr
22.0 bar6,499 US gallon
27.5 bar6,499 US gallon
34.4 bar6,419 US gallon
MAXIMUM GROSS WEIGHT
22.0 bar36,000 kgs
27.5 bar36,000 kgs
34.4 bar36,000 kgs
22.0 bar79,366 lbs
27.5 bar79,366 lbs
34.4 bar79,366 lbs
TARE WEIGHT
22.0 bar7,100 kgs
27.5 bar7,560 kgs
34.4 bar8,800 kgs

 

22.0 bar15,653 lbs
27.5 bar16,666 lbs
34.4 bar19,400 lbs
PAYLOAD
22.0 bar29,800 kgs
27.5 bar28,440 kgs
34.4 bar27,200 kgs

 

22.0 bar63,713 lbs
27.5 bar62,700 lbs
34.4 bar59,966 lbs
MAXIMUM ALLOWABLE WORKING PRESSURES
UN Portable22.0 bar

27.5 bar

34.4 bar

US DOT20.0 bar

25.0 bar

31.3 bar

Test Pressure29.9 bar

35.75 bar

44.72 bar

UN Portable319 psi

399 psi

499 psi

US DOT290 psi

363 psi

454 psi

Test Pressure433 psi

518 psi

648 psi

MAXIMUM CARGO TEMPERATURE
22.0 bar55°C
27.5 bar55°C
34.4 bar55°C
22.0 bar131°F
27.5 bar131°F
34.4 bar131°F
AMBIENT TEMPERATURE RANGE
22.0 bar-40°C to +55°C
27.5 bar-40°C to +55°C
34.4 bar-40°C to +55°C
22.0 bar-40°F to +131°F
27.5 bar-40°F to +131°F
34.4 bar-40°F to +131°F